PEDESTRIAN FACILITIES (SHEET 1 OF 12)

sidewalk is 25%. buffer zones with a cross slope greater than 25% should be paved, planted 14. the maximum recommended cross slope of a turf buffer zone or slope transition behind hardscape materials. exclusive of curb, is less than 3'-0 , the surface should be paved or constructed with vehicle traveled way. the buffer zone may be planted or paved.

Design Review Checklist Site Fine Grading

Dec 31, 2013 A.7 Maximum longitudinal slope for driveways is 12.5%. Maximum cross slope for driveways is ½ in 12 Minimum longitudinal slope for driveways is 1%. Minimum cross slope for driveways is 1/8 in 12 Code 32-151 A.8 Maximum longitudinal sidewalk slope is 12H:1V (8.33%). Maximum cross slope for sidewalks is 48H:1V (2.0%) Code 32-151

MDOT Standards and the Americans With Disabilities Act

Maximum Ramp Slope (8.3%) is Relative to Flat (0%) Slope. Not Sidewalk Slope. 15 FT. MINIMUM Maximum ramp slope is 8.3%. However, it shall not require any ramp or single ramp within a combination of ramps to exceed 15 feet in length. You may exceed 8.3% if it takes more than 15 ft. to match existing sidewalk.

113-10 Sidewalk Compliance

Slope column: If the value calculated in the Slope column falls outside of the Acceptable Range for that sidewalk piece, the value will turn color to indicate that the design is out of compliance. Sidewalk Design Adjustments If any Slope column is highlighted, the design needs to be adjusted. It is suggested that the designer

ADA Post Construction Inspection Checklist

Sidewalk cross slopes are 2.0% or less. For example, a segment with the maximum allowed running slope of 8.33% would require 5 x 5 landing every 30 Sidewalk running slopes meet any of the following conditions: - The sidewalk is at the same grade as the roadway, regardless how steep the roadway grade is.

ADA FIELD GUIDE - Charlotte, NC

Ramp Cross Slope = match roadway grade (in alteration, ideally 2%) Flare Slope = 10.00% or less Detectable Warning Surface = 2 foot minimum length x full width of ramp Sidewalk cross slope = 2.00% or less Gutter slope = 8.33% or less* (see pg. 11)

Pedestrian Path Guidelines:Safety Rail

Slope surfaces consisting of rough materials, such as revetment, adjacent to pedestrian a path. The presence of traffic or a body of water at the bottom of a slope adjacent to a pedestrian path. In Areas with Maintenance Personnel Only These areas are not expected to receive any pedestrian travel but may be serviced by maintenance

General Ramp Specifications IV - SC DHHS

A 1:10 slope is permitted for no more than a 6 rise. A 1:8 slope is permitted for no more than a 3 rise. Ramps: Shall not rise more than 30 between landings. Shall lead to a firm stable landing, provider is responsible for the area at the end of a ramp. Shall be level with a cross slope of no more than 1:50 Shall have a clear width of

Bellevue s ADA Sidewalk and Curb Ramp Compliance Program

Sidewalk Cross Slope: As indicated in Figure 5, over 50 percent of Bellevue s 8 plus percent cross slope measurements are attributable to driveway aprons. This number increases as cross slope values increase, with 70 percent of 10 plus percent cross slope measurements attributable to driveway aprons. Overall, 19 percent of all non-standard

Sidewalk Repair Manual - Watertown

some areas, sidewalk sections are lifted up due to the growth of tree roots. If you grind down a stub toe caused by tree roots, the repair may only be temporary. Grind off the stub toe so that the concrete and/or sidewalk has a gradual slope or transition. For one half an inch (1/2 ) of rise, grind back six inches (6 ).

Section 7030 - Sidewalks, Shared Use Paths, and Driveways

sidewalk. 3. Includes: Unit price includes, but is not limited to, minor grade adjustments at driveways and other intersections, subgrade preparation, formwork, additional thickness at thickened edges, jointing, sampling, slope and smoothness testing and correction, and testing. F. Brick/Paver Sidewalk with Pavement Base: 1.

Sidewalk Design: ADA Considerations - EMC Ins

May 10, 2011 the sidewalk, can be especially beneficial to visually impaired pedestrians and to wheelchair users. Sidewalks should be kept in good condition, free from debris, cracks and rough surfaces. To the extent possible, sidewalks should have a maximum cross-slope of 1 inch of fall for every 4 feet of width (2 percent grade). A person using crutches or

Town of Culver 202 Sidewalk & Curb Program Application

Slope Maximum Sidewalk or ramp slope, shall adhere to ADA standards (NO SLOPE SHALL EXCEED 1:12, maximum slope may not be exceeded for a maximum distance of 30 feet). All walks shall have a minimum 1/4 cross slope for drainage. Scoring and Jointing Areas with the potential for differential settling should be identified and expansion joints and

ADA Field Guide 2012 Edition - wsdot.wa.gov

Running slope 8.3% maximum (the ramp length is not required to exceed 15 feet along the sidewalk). Cross slope 2% maximum. Exception: Cross slopes of curb ramps at midblock crossings are allowed to match the street or highway grade. Required landing (at top of perpendicular curb ramp, at bottom of parallel curb ramp): 4 feet by 4 feet minimum.

INSTRUCTIONS FOR FILING PLANS - NYC

3) Longitudinal slope a) Access for people with disabilities: The smooth slope may be interrupted at the entrance of a building to provide for a flush entryway, subject to DOT approval. 4) Drainage from private property a) Drainage across the public right-of-way: Not allowed. b) Drainage under the sidewalk: In compliance with all applicable

SIDEWALK AND CURB RAMP DETAILS (SHEET 1 OF 9)

12. the cross slope of pedestrian access routes shall be 1.5% maximum for highway grade. highway grade is greater than 5%, the sidewalk grade shall not exceed the when matching into existing sidewalk or when the highway grade is steeper. when 11. sidewalk grade (running slope) shall not be designed to exceed 4.5%, except

Making Impossible ADA Slopes Possible

any slope over five percent is considered a ramp (ramps are required to have edge protectors and handrails, and must be limited in length; with 8.3 percent maximum slope for ramps no more than 9 m (30 ft) long or 762 mm (30 in.) vertical in height the bottom and top ends of the ramp is required to

TEXAS ACCESSIBILITY STANDARDS (TAS)

4.3.7 Slope. An accessible route with a running slope greater than 1:20 is a ramp and shall comply with 4.8. Nowhere shall the cross slope of an accessible route

Sidewalk Cross-Slope Design: Analysis of Accessibility (4171-S)

4171-1: Sidewalk Cross-Slope Design: Analysis of Accessibility for Persons with Disabilities (in progress at CTR) 4933-S: Methods for Meeting the ADA in Sidewalk Cross-Slope Design. Published, peer-reviewed summaries of the earlier work can also be found in the Journal of Rehabilitation Research and Development 38 (2001)

A B PLAN SECTION A-A TYPICAL SIDEWALK SECTION SECTION B-B

6 the running slope of the sidewalk is equal to the street grade or flatter. cross slope of the sidewalk, ramp, or landing is 2% (1:50). 5 the desirable cross slope of the sidewalk, ramp, or landing is 1.5% (1:66.7) or less. the maximum constructed flared side slope is 10% (1:10).

PennDOT Pedestrian Facilities Pocket Guide

the sidewalk slope. 8. To avoid chasing grade indefinitely when traversing the height of curb, ramp length not to exceed 15'-0 Adjust ramp slope as needed to provide access to the maximum extent feasible. 9. Non-walk area is an obstructed or grass/non-paved area adjacent to the pedestrian access route that is not used by the pedestrian for

Design Manual Roadway Section 5 - NJ

Sep 19, 2008 The cross slope of the pavement is the slope of the pavement surface measured transverse to the centerline of the highway. The high point of a normal cross slope of a roadway is known as the crown. Undivided pavements on tangents or on flat curves have a high point (crown) in the middle of the traveled way and slope downward toward both edges.

accessible sidewalks crossings

U The cross slope of a sidewalk should not exceed 1:48 (2%). Excessive cross slope requires additional energy to counteract and tends to direct wheelchair users into the street, particularly when it is wet, icy, or snowy underfoot. At driveways there should be a minimum 36-inch (915 mm) wide passage with a cross slope of no more than 1:48 (2%).

Walkways - QUIKRETE

How to Build a Concrete Sidewalk 1n Select a rough layout, including any turns. Stake out the location and connect the stakes with mason s strings. Set the slope, if needed. Remove sod between and 6 beyond the lines, then excavate the site with a spade to a depth 4 greater than the thickness of the concrete walkway, following the

Sidewalk Cross-Slope Design: Analysis of Accessibility for

slope on sidewalk users with disabilities was noted as far back as 1979 (Brown et al. 1979). Related studies have relied on populations of young males, providing little information on maximum limits for the broadest range of sidewalk users with disabilities, particularly in an

Sidewalk and Driveway Standard Plan 5-297-

indicates driveway ramp - slope shall variable section c-c 5.0' par residential. see general notes on sheet 2 for more information. 8% max. preferred, 10% max. for commercial and 12% max. for 8% max. preferred, see sheet 2 for more information. 1:10 preferred for sidewalk replacement projects. 1:3 min. 1:5 preferred for driveway retrofit projects.

2020 MN Accessibility Code Summary

Curb ramps shall have a maximum slope of 1:12. The running slope of the curb ramp shall be in-line with the direction of sidewalk travel. The curb ramp run length shall not exceed 7 feet. A landing shall be provided at the top of the curb ramp that measure at least 3 feet in length.

Accessible Sidewalks and Street Crossings

The Sidewalk Corridor is the portion of the pedestrian system from the edge of the roadway to the edge of the right-of-way (property line or building edge), generally parallel to the street. Attributes of good sidewalk corridor design include: Accessibility by ALL users. Adequate width.

ITEM MIN MAX STANDARD REASON* GUIDANCE

Jan 12, 2018 SIDEWALK RUNNING SLOPE 5.0% - C, M & U For sidewalk running slopes, the max. running slope is 5% (unless roadway grade is steeper). SIDEWALK RAMP SLOPE 5.0% 8.3% 7.0% C, M & U Only for sidewalk not adjacent to roadway. A landing is needed for every 30 of

SECTION 22 ADA COMPLIANCE FOR SIDEWALK, CURB RAMPS, BLENDED

2. The grade (running slope) of the sidewalk may match the adjacent roadway profile grade. 3. A curb ramp running slope of 10% for a 6in. rise is not acceptable. - 4. A sidewalk adjacent to a roadway does not require a landing area or handrail, regardless of the roadway grade. 5. Detectable warning elements must extend the full width of the ramp.

ADA Curb Ramps

A: Sidewalk cross slope 2% max and 4 width min. (1.5% INDOT Constructibility) 8: Running slope blended transition 5% max (4.5% INDOT Constructibility) C: Running slope sidewalk transition D: Flare slope 10% max E: Cross slope btw. sidewalk and Blended transition 2% max (1.5% INDOT Constructibility DSDAVIS DSDAVIS 2:34 AM C:' Arrow DSDAVIS 2:40 AM

CHAPTER 9: SIDEWALK DESIGN

9.3 Sidewalk Design Figure 9.1 shows guidelines for the design of sidewalks, including width and cross slopes. Sidewalk Buffer Zone A pedestrian s safety and comfort in the roadway environment is largely dependent on the width and quality of the buffer between the sidewalk and the roadway. Physical barriers between the sidewalk and roadway

PERMANENT PEDESTRIAN FACILITIES ADA COMPLIANCE HANDBOOK

0.2 percent of the compliance slope value is deemed acceptable. For percent and the maximum ADA compliance value of the slope is known to be 2.0 percent. If all three of the measured slopes are 1.7 percent (1.5 percent + 0.2 percent [tool accuracy]) or less, contract and ADA compliance have been achieved.

Florida Department of Transportation

One consistent requirement is the maximum cross-slope of a sidewalk must be no greater than 2% (actually, 1:48). (of of of , of ((((: The

Slope Conversion Tables - LascoLaser.com

Slope Conversion Tables 1/4 1/2 3/4 1 1-1/4 1-1/2 1-3/4 2 2-1/2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 3 4 5 6 7 8 9 10

Builders Pavement Plans - New York City

Gutter (longitudinal) slope at least 0.5% shown in profile view with elevations shown 50 each way from lot lines for large developments Full concrete sidewalks provided for zoning districts C, M and R6 and higher 13 to 15 wide sidewalk provided for 60 wide mapped streets

Measuring Walkability: Development of an Automated Sidewalk

variables for measuring walkability, included sidewalk presence, sidewalk width, running slope, and presence of a buffer between the sidewalk and motor vehicle traffic (Meghelal and Capp 2011). Traditional methods of sidewalk inventory are often time and cost-prohibitive, particularly for large-scale implementation.

Sidewalk Rehabilitation Program

Cross Slope Question: Why does the City remove sidewalk for excessive cross slope? Answer: The City of Oshkosh follows ADA requirements which allows for a maximum cross slope of 2% or ¼ per foot. In most cases, the sidewalk not meeting this requirement must be removed and replaced. The ADA acceptable slope for a sidewalk is 1% to 2% 19

Attachment 11 ADA Transition - Mass.gov

Apr 03, 2018 sidewalk. is a walk immediately adjacent to a roadway or offset from the roadway by a uniform planting strip. The sidewalk profile is controlled by the roadway profile with minimal ability to make adjustments. By regulation of the AAB if the slope of the natural topography. exceeds one-in-20 (1:20) (5%) a ramp is not required for a